• Card 3 / 35: A fluid with heat capacity 2.2 kJ/kg K enters a heat exchanger at 90°C and leaves at 30°C at a flow rate of 5 kg/s. Calculate the heat removal from this fluid.
    A) 660 W
    B) 6.60 kW
    C) 66.0 kW
    D) 660 kW
    E) 66.0 W

    Answer:
    D) 660 kW

  • Keyboard Shortcuts

    Previous Card ← Previous Card Button
    Next Card → Next Card Button
    Flip Card Space-Bar
<< First < Previous Next > Last >>

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now
Explanation:

Q = 5 kg/s (2.2kJ/kg K)(60 K) = 660 kW

Hide Choices Interactive Question Quiz Home Page
https://www.jobilize.com/thermal-fluid-systems-mcq-quiz-by-dr-steve-gibbs

Thermal-Fluid Systems ME303

Author:

Access: Public Instant Grading

Attribution:  Dr. Steve Gibbs. Thermal-Fluid Systems. The Saylor Academy 2014, http://www.saylor.org/courses/me303/
Flash Cards plugin by Curtis Blackwell github.com/curtisblackwell/flash_cards
Google Play and the Google Play logo are trademarks of Google Inc.
Ask
Copy and paste the following HTML code into your website or blog.
<iframe src="https://www.jobilize.com/embed/thermal-fluid-systems-mcq-quiz-by-dr-steve-gibbs" width="600" height="600" frameborder="0" marginwidth="0" marginheight="0" scrolling="yes" style="border:1px solid #CCC; border-width:1px 1px 0; margin-bottom:5px" allowfullscreen webkitallowfullscreen mozallowfullscreen> </iframe>