• Card 2 / 35: A countercurrent heat exchanger operates with the following temperatures: cold fluid inlet 15°C, cold fluid outlet 25°C, hot fluid inlet 90°C, and hot fluid outlet 30°C. Calculate the logarithmic-mean temperature difference in °C.
    A) 45°C
    B) 30°C
    C) 27°C
    D) 25°C
    E) 50°C

    Answer:
    C) 27°C

  • Keyboard Shortcuts

    Previous Card ← Previous Card Button
    Next Card → Next Card Button
    Flip Card Space-Bar
<< First < Previous Next > Last >>

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now
Explanation:

The temperature differences at the termini are ΔT1 = 90-25 = 65 °C and ΔT2=30-15 = 15 °C. Hence,ΔTlm = ΔT1- ΔT2/ln(ΔT1/ ΔT2)= 27.3 °C.

Hide Choices Interactive Question Quiz Home Page
https://www.jobilize.com/thermal-fluid-systems-mcq-quiz-by-dr-steve-gibbs

Thermal-Fluid Systems ME303

Author:

Access: Public Instant Grading

Attribution:  Dr. Steve Gibbs. Thermal-Fluid Systems. The Saylor Academy 2014, http://www.saylor.org/courses/me303/
Flash Cards plugin by Curtis Blackwell github.com/curtisblackwell/flash_cards
Google Play and the Google Play logo are trademarks of Google Inc.
Ask
Jugnu Khan
Start Quiz
Madison Christian
Start Exam
Edgar Delgado
Start Quiz
Copy and paste the following HTML code into your website or blog.
<iframe src="https://www.jobilize.com/embed/thermal-fluid-systems-mcq-quiz-by-dr-steve-gibbs" width="600" height="600" frameborder="0" marginwidth="0" marginheight="0" scrolling="yes" style="border:1px solid #CCC; border-width:1px 1px 0; margin-bottom:5px" allowfullscreen webkitallowfullscreen mozallowfullscreen> </iframe>