<< Chapter < Page Chapter >> Page >

Introduction

Ion selective electrode (ISE) is an analytical technique used to determine the activity of ions in aqueous solution by measuring the electrical potential. ISE has many advantages compared to other techniques, including:

  1. It is relatively inexpensive and easy to operate.
  2. It has wide concentration measurement range.
  3. As it measure the activity, instead of concentration, it is particularly useful in biological/medical application.
  4. It is a real-time measurement, which means it can monitor the change of activity of ion with time.
  5. It can determine both positively and negatively charged ions.

Based on these advantages, ISE has wide variety of applications, which is reasonable considering the importance of measuring ion activity. For example, ISE finds its use in pollution monitoring in natural waters (CN - , F - , S - , Cl - , etc.), food processing (NO 3 - , NO 2 - in meat preservatives), Ca 2+ in dairy products, and K + in fruit juices, etc.

Measurement setup

Before focusing on how ISE works, it would be good to get an idea what ISE setup looks like and the component of the ISE instrument. [link] shows the basic components of ISE setup. It has an ion selective electrode, which allows measured ions to pass, but excludes the passage of the other ions. Within this ion selective electrode, there is an internal reference electrode ( [link] ), which is made of silver wire coated with solid silver chloride, embedded in concentrated potassium chloride solution (filling solution) saturated with silver chloride. This solution also contains the same ions as that to be measured. There is also a reference electrode similar to ion selective electrode, but there is no to-be-measured ion in the internal electrolyte and the selective membrane is replaced by porous frit, which allows the slow passage of the internal filling solution and forms the liquid junction with the external text solution. The ion selective electrode and reference electrode are connected by a milli-voltmeter. Measurment is accomplished simply by immersing the two electrodes in the same test solution.

Measurement setup of ISE.

Theory of how ise works

There are commonly more than one types of ions in solution. So how ISE manage to measure the concentration of certain ion in solution without being affected by other ions? This is done by applying a selective membrane at the ion selective electrode, which only allows the desired ion to go in and out. At equilibrium, there is potential difference existing between two sides of the membrane, and it is governed by the concentration of the tested solution described by Nernst equation EQ, where E is potential, E 0 is a constant characteristic of a particular ISE, R is the gas constant (8.314 J/K.mol), T is the temperature (in K), n is the charge of the ion and F is Faraday constant (96,500 coulombs/mol). To make it relevant, the measured potential difference is proportional to the logarithm of ion concentration. Thus, the relationship between potential difference and ion concentration can be determined by measuring the potential of two solutions of already-known ion concentration and a plot based on the measured potential and logarithm of the ion concentration. Based on this plot, the ion concentration of an unknown solution can be known by measuring the potential and corresponding it to the plot.

Questions & Answers

A golfer on a fairway is 70 m away from the green, which sits below the level of the fairway by 20 m. If the golfer hits the ball at an angle of 40° with an initial speed of 20 m/s, how close to the green does she come?
Aislinn Reply
cm
tijani
what is titration
John Reply
what is physics
Siyaka Reply
A mouse of mass 200 g falls 100 m down a vertical mine shaft and lands at the bottom with a speed of 8.0 m/s. During its fall, how much work is done on the mouse by air resistance
Jude Reply
Can you compute that for me. Ty
Jude
what is the dimension formula of energy?
David Reply
what is viscosity?
David
what is inorganic
emma Reply
what is chemistry
Youesf Reply
what is inorganic
emma
Chemistry is a branch of science that deals with the study of matter,it composition,it structure and the changes it undergoes
Adjei
please, I'm a physics student and I need help in physics
Adjanou
chemistry could also be understood like the sexual attraction/repulsion of the male and female elements. the reaction varies depending on the energy differences of each given gender. + masculine -female.
Pedro
A ball is thrown straight up.it passes a 2.0m high window 7.50 m off the ground on it path up and takes 1.30 s to go past the window.what was the ball initial velocity
Krampah Reply
2. A sled plus passenger with total mass 50 kg is pulled 20 m across the snow (0.20) at constant velocity by a force directed 25° above the horizontal. Calculate (a) the work of the applied force, (b) the work of friction, and (c) the total work.
Sahid Reply
you have been hired as an espert witness in a court case involving an automobile accident. the accident involved car A of mass 1500kg which crashed into stationary car B of mass 1100kg. the driver of car A applied his brakes 15 m before he skidded and crashed into car B. after the collision, car A s
Samuel Reply
can someone explain to me, an ignorant high school student, why the trend of the graph doesn't follow the fact that the higher frequency a sound wave is, the more power it is, hence, making me think the phons output would follow this general trend?
Joseph Reply
Nevermind i just realied that the graph is the phons output for a person with normal hearing and not just the phons output of the sound waves power, I should read the entire thing next time
Joseph
Follow up question, does anyone know where I can find a graph that accuretly depicts the actual relative "power" output of sound over its frequency instead of just humans hearing
Joseph
"Generation of electrical energy from sound energy | IEEE Conference Publication | IEEE Xplore" ***ieeexplore.ieee.org/document/7150687?reload=true
Ryan
what's motion
Maurice Reply
what are the types of wave
Maurice
answer
Magreth
progressive wave
Magreth
hello friend how are you
Muhammad Reply
fine, how about you?
Mohammed
hi
Mujahid
A string is 3.00 m long with a mass of 5.00 g. The string is held taut with a tension of 500.00 N applied to the string. A pulse is sent down the string. How long does it take the pulse to travel the 3.00 m of the string?
yasuo Reply
Who can show me the full solution in this problem?
Reofrir Reply
Got questions? Join the online conversation and get instant answers!
Jobilize.com Reply

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Physical methods in chemistry and nano science. OpenStax CNX. May 05, 2015 Download for free at http://legacy.cnx.org/content/col10699/1.21
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Physical methods in chemistry and nano science' conversation and receive update notifications?

Ask