• Card 24 / 35: How do pumps and fans/blowers differ?
    A) By size
    B) By operating pressures
    C) By operating speeds
    D) By cost
    E) By types of operating fluids

    Answer:
    E) By types of operating fluids

  • Keyboard Shortcuts

    Previous Card ← Previous Card Button
    Next Card → Next Card Button
    Flip Card Space-Bar
<< First < Previous Next > Last >>

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now
Explanation:

Pumps tend to work on incompressible fluids, but blowers typically work on compressible fluids.

Hide Choices Interactive Question Quiz Home Page
https://www.jobilize.com/thermal-fluid-systems-mcq-quiz-by-dr-steve-gibbs

Thermal-Fluid Systems ME303

Author:

Access: Public Instant Grading

Attribution:  Dr. Steve Gibbs. Thermal-Fluid Systems. The Saylor Academy 2014, http://www.saylor.org/courses/me303/
Flash Cards plugin by Curtis Blackwell github.com/curtisblackwell/flash_cards
Google Play and the Google Play logo are trademarks of Google Inc.
Ask
Madison Christian
Start Flashcards
Dewey Compton
Start Exam
Copy and paste the following HTML code into your website or blog.
<iframe src="https://www.jobilize.com/embed/thermal-fluid-systems-mcq-quiz-by-dr-steve-gibbs" width="600" height="600" frameborder="0" marginwidth="0" marginheight="0" scrolling="yes" style="border:1px solid #CCC; border-width:1px 1px 0; margin-bottom:5px" allowfullscreen webkitallowfullscreen mozallowfullscreen> </iframe>