<< Chapter < Page Chapter >> Page >
  • Describe some applications of magnetism.

Mass spectrometry

The curved paths followed by charged particles in magnetic fields can be put to use. A charged particle moving perpendicular to a magnetic field travels in a circular path having a radius r size 12{r} {} .

r = mv qB size 12{r= { { ital "mv"} over { ital "qB"} } } {}

It was noted that this relationship could be used to measure the mass of charged particles such as ions. A mass spectrometer is a device that measures such masses. Most mass spectrometers use magnetic fields for this purpose, although some of them have extremely sophisticated designs. Since there are five variables in the relationship, there are many possibilities. However, if v size 12{v} {} , q size 12{q} {} , and B size 12{B} {} can be fixed, then the radius of the path r size 12{r} {} is simply proportional to the mass m size 12{m} {} of the charged particle. Let us examine one such mass spectrometer that has a relatively simple design. (See [link] .) The process begins with an ion source, a device like an electron gun. The ion source gives ions their charge, accelerates them to some velocity v size 12{v} {} , and directs a beam of them into the next stage of the spectrometer. This next region is a velocity selector that only allows particles with a particular value of v size 12{v} {} to get through.

Diagram of a mass spectrometer. Ions travel to the right with velocity v from the ion source. Magnetic field lines come out of the page between two charged plates on either side of the ion beam. The electric force F equals q E acts on the ions in an upward direction while the magnetic force F equals q v B acts in a downward direction. The forces have the same magnitude and thus the ions travel in a straight line between the two plates. The ions then enter another region where the magnetic field lines come out of the page. An ion of mass 1 curves around, traveling a net distance of 2 r 1. An ion of mass 2 curves around, traveling a net distance of 2 r 2.
This mass spectrometer uses a velocity selector to fix v size 12{v} {} so that the radius of the path is proportional to mass.

The velocity selector has both an electric field and a magnetic field, perpendicular to one another, producing forces in opposite directions on the ions. Only those ions for which the forces balance travel in a straight line into the next region. If the forces balance, then the electric force F = qE size 12{F= ital "qE"} {} equals the magnetic force F = qvB size 12{F= ital "qvB"} {} , so that qE = qvB size 12{ ital "qE"= ital "qvB"} {} . Noting that q size 12{q} {} cancels, we see that

v = E B size 12{v= { {E} over {B} } } {}

is the velocity particles must have to make it through the velocity selector, and further, that v size 12{v} {} can be selected by varying E size 12{E} {} and B size 12{B} {} . In the final region, there is only a uniform magnetic field, and so the charged particles move in circular arcs with radii proportional to particle mass. The paths also depend on charge q size 12{q} {} , but since q size 12{q} {} is in multiples of electron charges, it is easy to determine and to discriminate between ions in different charge states.

Mass spectrometry today is used extensively in chemistry and biology laboratories to identify chemical and biological substances according to their mass-to-charge ratios. In medicine, mass spectrometers are used to measure the concentration of isotopes used as tracers. Usually, biological molecules such as proteins are very large, so they are broken down into smaller fragments before analyzing. Recently, large virus particles have been analyzed as a whole on mass spectrometers. Sometimes a gas chromatograph or high-performance liquid chromatograph provides an initial separation of the large molecules, which are then input into the mass spectrometer.

Cathode ray tubes—crts—and the like

What do non-flat-screen TVs, old computer monitors, x-ray machines, and the 2-mile-long Stanford Linear Accelerator have in common? All of them accelerate electrons, making them different versions of the electron gun. Many of these devices use magnetic fields to steer the accelerated electrons. [link] shows the construction of the type of cathode ray tube (CRT) found in some TVs, oscilloscopes, and old computer monitors. Two pairs of coils are used to steer the electrons, one vertically and the other horizontally, to their desired destination.

Practice Key Terms 4

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Introductory physics - for kpu phys 1100 (2015 edition). OpenStax CNX. May 30, 2015 Download for free at http://legacy.cnx.org/content/col11588/1.13
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Introductory physics - for kpu phys 1100 (2015 edition)' conversation and receive update notifications?

Ask