Frequency response palette:

The VIs in this sub-palette that are used most frequently are CD Bode, CD Nyquist, and CD Gain and PhaseMargins. These VIs are frequently used in Chapter 6, and are also polymorphic.

Cd bode.vi:

This VI gives the Bode Magnitude and Phase plots of a system, and the input is the open loop model.

The output terminals that are of interest are the ones for plotting the Magnitude and Phase graphs. These can beplotted by creating indicators for the respective terminals. The magnitude plot is shown here.

Cd nyquist.vi:

This VI gives the Nyquist plot of a system.

Remember to right-click on the output terminal of CD Nyquist and select Create»Indicator to create the Nyquist Plot indicator.

Cd gain and phase margin.vi:

This VI gives the Gain and Phase Margins of a system, along with the Magnitude and Phase graph indicating theposition where the Gain and Phase Margins occur.

The numerator has been changed so that the function has a valid Phase Margin.

The Gain and Phase margins are shown in a numeric indicator as shown.

The Magnitude graph obtained from the Block Diagram above is shown below. The zero crossing of the magnitude isindicated in the plot.

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Introduction to control design and simulation using labview. OpenStax CNX. Jan 29, 2007 Download for free at http://cnx.org/content/col10401/1.1
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Introduction to control design and simulation using labview' conversation and receive update notifications?

Ask