Define effective length

The equations for critical buckling load include the variable KL which is the effective length . K is the effective length factor . Values for K vary depending on the load and type of supports of a member. A listing of the valuescan be found in the Manual on page 16.1-189 in Table C-C2.1. For instance, the value for K with the condition that both ends of a column are rotation free and translation fixed(pinned) is 1.0.

"Two values for K are given: a theoretical value and a recommended design value to be usedwhen the ideal end condition is approximated. Hence, unless a 'fixed' end is perfectly fixed, the more conservativedesign values are to be used. Only under the most extraordinary circumstances would the use of the theoreticalvalues be justified. Note, however, that the theoretical and recommended design values are the same for conditions(d) and (f) in the Commentary Table C-C2.1. The reason is that any deviation from a perfectly frictionless hinge orpin introduces rotational restraint and tends to reduce K . Therefore use of the theoretical values in these two cases is conservative." LRFD Steel Design Second Edition: William T. Segui, 1999

The larger the effective length, the less strength there is in a column. So, if there is a choice ofeffective lengths, the larger value will give the more conservative strength value.

Actual length vs. effective length

Sometimes the actual length of a member differs from the effective length. This is true when a member is supportedsomewhere in the middle in addition to at the two ends. The effective length then, is the length from one support toanother. Also, a member can be supported two different ways in two different axes. For example, a column can besupported at the top in the bottom while looking at it in the x-direction, but braced in the middle when looking at itfrom the y-direction. We refer to the distance between the supports in the y-direction and the x-direction as L y and L x , respectively.

Using kl(x)

The design strengths given in the column load tables beginning on page 4-21 are based on the effective lengthwith respect to the y-axis. A procedure was developed (as follows) to use K x L in the tabulated values.

The tablulated values in chapter 4 of the Manual are in terms of the y-axis being the stong axis. This means they are based on the values of KL being equal to K y L . However, if a situation occurs where one would need the values of KL with respect to the x-axis, the following procedure can be used.

The KL as tabulated is equal to either K y L or K x L r x r y . We can obtain K x L r x r y by:

  • KL y r y
  • y r y r x
  • KL y KL r y r x
  • K x L r x r y KL y

Get Jobilize Job Search Mobile App in your pocket Now!

Get it on Google Play Download on the App Store Now




Source:  OpenStax, Steel design (civi 306). OpenStax CNX. Jan 22, 2004 Download for free at http://cnx.org/content/col10153/1.3
Google Play and the Google Play logo are trademarks of Google Inc.

Notification Switch

Would you like to follow the 'Steel design (civi 306)' conversation and receive update notifications?

Ask